100G QSFP28 2km CWDM4 Features . Compliant with 100G CWDM4 MSA Specification . Uncooled 4x25Gb/s CWDM transmitter . Wide Operating Temperature(0°C~70°C) . Maximum link length of 2km via Single Mode Fiber (SMF)
PRICE: US$123.00-140.00/1 Piece (MOQ)

100G QSFP28 2km CWDM4
Features
. Compliant with 100G CWDM4 MSA Specification
. Uncooled 4x25Gb/s CWDM transmitter
. Wide Operating Temperature(0°C~70°C)
. Maximum link length of 2km via Single Mode Fiber (SMF)
Applications
. Data Center Backbone
. Ethernet Switches
. High-speed Servers
. High-performance Computing Clusters
. SAN, Routers, Hubs, Load Balancer
| Parameter | Symbol | Conditions | Min. | Max. | Unit |
| Storage Temperature | TStorage | -40 | +85 | °C | |
| Relative Humidity | RH | 0 | +85 | % |
| Parameter | Symbol | Conditions | Min. | Typ. | Max. | Unit |
| Case Temperature | TC | 0 | 70 | °C | ||
| Power Supply Voltage | VCC | 3.135 | 3.3 | 3.465 | V | |
| Signaling Rate each Channel | 25.78125 | Gbps | ||||
| Supply Noise Rejection | — | — | 100 | mV | ||
| Receiver Differential Data Output | — | 100 | Ohm | |||
| Operating Distance | D | — | — | 2 | km |
| Parameter | Symbol | Conditions | Min. | Typ. | Max. | Unit |
| Signaling rate, each lane (range) | GBb | 25.78125 | GBb | |||
| Center Wavelength | λ0 | 1264.5 | 1277.5 | nm | ||
| λ1 | 1284.5 | 1297.5 | nm | |||
| λ2 | 1304.5 | 1317.5 | nm | |||
| λ3 | 1324.5 | 1337.5 | nm | |||
| Side-mode suppression ratio | SMSR | 30 | dB | |||
| Total average launch power | 8.5 | dBm | ||||
| Average launch power, each lane | Pf | -6.5 | 2.5 | dBm | ||
| Optical Modulation Amplitude (OMA), each lane | TxOMA | -4 | 2.5 | dBm | ||
| Transmitter and Dispersion Pen- alty | TDP | 3 | dB | |||
| Launch power in OMA minus TDP, each lane | Tx-TDP | -5 | dBm | |||
| Average launch power of OFF transmitter, each lane | -30 | dBm | ||||
| Extinction ratio | ER | 3.5 | dB | |||
| Optical return loss tolerance | 20 | dB | ||||
| Transmitter reflectance | -12 | dB |
| Parameter | Symbol | Conditions | Min. | Typ. | Max. | Unit |
| Signaling rate, each lane (range) | GBb | 25.78125 | GBb | |||
| Center Wavelength | λ0 | 1264.5 | 1277.5 | nm | ||
| λ1 | 1284.5 | 1297.5 | nm | |||
| λ2 | 1304.5 | 1317.5 | nm | |||
| λ3 | 1324.5 | 1337.5 | nm | |||
| Damage threshold | 3.5 | dBm | ||||
| Average power at receiver input, each lane | -10 | 2.5 | dBm | |||
| Receive power, each lane (OMA) | 2.5 | dBm | ||||
| Receiver reflectance | -26 | dB | ||||
| Receiver sensitivity (OMA) | SOMA | BER@5e-5 | -10 | dBm | ||
| LOS Assert | LOSA | -24 | dBm | |||
| LOS De-Assert | LOSD | -11.6 | dBm | |||
| LOS Hysteresis | 0.5 | 6 | dB |